Kingsman ZCVRB47/60/72
Available in 47, 60, and 72 inch sizes
STANDARD FEATURES
Adjustable heat and flame size
IPI valve system operates during power failures
- Safety Screen Barrier
REQUIRED MEDIA
- Crushed Glass (your choice of colour)
OPTIONAL ACCESSORIES
- Fan Kit
- Heat Activated with Variable Speed Control
- Light Kit
- Accent Lighting Lamps (bottom)
- ZCVRB47: Two Lamps
- ZCVRB60/72: Four Lamps
- Accent Lighting Lamps (bottom)
- Liner
- Surrounds
- Trim - narrow (4-sided) black or stainless steel
- Vented Chase
- For Cool Touch Walls and Reduced Mantel/TV Clearances
OPTIONAL MEDIA
- Cannonballs (for use on top of Crushed Glass)
CONTROL METHODS
- Wall Switch
- On/Off
- Wall Mount Thermostats
- On/Off Digital
- Programmable Digital 5 day (weekday) and 2 day (weekend)
- Remote Controls
- On/Off with Thermostat
- On/Off with Thermostat & Flame Modulation
- On/Off with Thermostat, Flame Modulation & Fan Speed Control
CLICK HERE FOR MORE INFO ON PRODUCT SPECS, BROCHURES & MANUALS
Tech Specs
Model ZCVRB47NE ZCVRB47LPE ZCVRB60NE ZCVRB60LPE ZCVRB72NE ZCVRB72LPE Fuel Natural Propane Natural Propane Natural Propane Gas Control IPI PF1 IPI PF1 IPI PF1 IPI PF1 IPI PF1 IPI PF1 Max BTU 24500 24500 35000 35000 50000 50000 Min BTU 16500 20500 23000 28000 34000 39000 Efficiency (P.4.1-15) 57.31% 57.1% 56.66% 56.66% 53.64% 53.64% Venting 4/7" Flex 4/7" Flex 5/8" Flex 5/8" Flex 5/8" Flex 5/8" Flex Viewing Area
Width Height ZCVRB47 40-5/8" 13-7/8” ZCVRB60 60" 17-7/8" ZCVRB72 73-1/16” 17-7/8" Framing Dimensions
Width Height Depth ZCVRB47 47” 38-3/4” 18-1/4”* ZCVRB60 67” 39-3/4” 19-1/4”* ZCVRB72 79-1/8” 42” 19”* *dependent on finishing material used
Base of Fireplace to Bottom of Viewing Area
ZCVRB47 ZCVRB60 ZCVRB72 Distance ~10" ~10" ~8-1/2" Optional Vented Chase - Opening with no Grills
ZCVRB47 ZCVRB60 ZCVRB72 Min. Chase Opening Free Air Area 105sq/in. 200sq/in. 285sq/in. Min. Enclosure Height (from bottom of FP) 70” 76” 79” Min. Opening Below Ceiling 1-1/4” 1-7/8” 2-3/8” NOTE: To vent the fireplace chase, removal of vent shields from the fireplace is required.
Optional Vented Chase - Opening with Grills
ZCVRB47 ZCVRB60 ZCVRB72 Min. Chase Opening Free Air Area 105sq/in. 220sq/in. 285sq/in. Min. Enclosure Height (from bottom of FP) 70” 76” 79” Grill Opening (Max. Distance from top of Enclosure) 2” 3/4” 3/4” NOTE: To vent the fireplace chase, removal of vent shields from the fireplace is required.
Optional Vented Chase - Grill Opening Dimensions
Width Height Front – ZCVRB47 46-3/4” 2-5/8” Front – ZCVRB60 60-5/8” 3-5/8” Front - ZCVRB72 78-5/8” 3-5/8” Sides – ZCVRB47/60 15-1/4” 6-5/8” Sides - ZCVRB72 15-1/4” 9" Surrounds
Border Width Border Width Coverage Coverage Sides Sides Top/Bottom W H ZCVRB47S1(BL/SS) 1-1/2" 1-1/2" 44-1/2" 18-7/8" 4 ZCVRB60S1(BL/SS) 1-1/2" 1-1/2" 64" 23" 4 ZCVRB72S1(BL/SS) 1-1/2" 1-1/2" 76-3/4" 23" 4