Kingsman ZCVRB47/60/72

Available in 47, 60, and 72 inch sizes

 

STANDARD FEATURES

  • Adjustable heat and flame size

  • IPI valve system operates during power failures

  • Safety Screen Barrier

 

REQUIRED MEDIA

 

OPTIONAL ACCESSORIES

  • Fan Kit
    • Heat Activated with Variable Speed Control
  • Light Kit
    • Accent Lighting Lamps (bottom)
      • ZCVRB47: Two Lamps
      • ZCVRB60/72: Four Lamps
  • Liner
  • Surrounds
    • Trim - narrow (4-sided) black or stainless steel
  • Vented Chase
    • For Cool Touch Walls and Reduced Mantel/TV Clearances

 

OPTIONAL MEDIA

 

CONTROL METHODS

  • Wall Switch
    • On/Off
  • Wall Mount Thermostats
    • On/Off Digital
    • Programmable Digital 5 day (weekday) and 2 day (weekend)
  • Remote Controls
    • On/Off with Thermostat
    • On/Off with Thermostat & Flame Modulation
    • On/Off with Thermostat, Flame Modulation & Fan Speed Control

 

CLICK HERE FOR MORE INFO ON PRODUCT SPECS, BROCHURES & MANUALS

  • Tech Specs

    Model ZCVRB47NE ZCVRB47LPE ZCVRB60NE ZCVRB60LPE ZCVRB72NE ZCVRB72LPE
    Fuel Natural Propane Natural Propane Natural Propane
    Gas Control IPI PF1 IPI PF1 IPI PF1 IPI PF1 IPI PF1 IPI PF1
    Max BTU 24500 24500 35000 35000 50000 50000
    Min BTU 16500 20500 23000 28000 34000 39000
    Efficiency (P.4.1-15) 57.31% 57.1% 56.66% 56.66% 53.64% 53.64%
    Venting 4/7" Flex 4/7" Flex 5/8" Flex 5/8" Flex 5/8" Flex 5/8" Flex

     

  • Viewing Area

      Width Height
    ZCVRB47 40-5/8" 13-7/8”
    ZCVRB60 60" 17-7/8"
    ZCVRB72 73-1/16” 17-7/8"

     

  • Framing Dimensions

      Width Height Depth
    ZCVRB47 47” 38-3/4” 18-1/4”*
    ZCVRB60 67” 39-3/4” 19-1/4”*
    ZCVRB72 79-1/8” 42” 19”*

    *dependent on finishing material used

  • Base of Fireplace to Bottom of Viewing Area

      ZCVRB47 ZCVRB60 ZCVRB72
    Distance ~10" ~10" ~8-1/2"

     

  • Optional Vented Chase - Opening with no Grills

      ZCVRB47 ZCVRB60 ZCVRB72
    Min. Chase Opening Free Air Area 105sq/in. 200sq/in. 285sq/in.
    Min. Enclosure Height (from bottom of FP) 70” 76” 79”
    Min. Opening Below Ceiling 1-1/4” 1-7/8” 2-3/8”

    NOTE: To vent the fireplace chase, removal of vent shields from the fireplace is required.

  • Optional Vented Chase - Opening with Grills

      ZCVRB47 ZCVRB60 ZCVRB72
    Min. Chase Opening Free Air Area 105sq/in. 220sq/in. 285sq/in.
    Min. Enclosure Height (from bottom of FP) 70” 76” 79”
    Grill Opening (Max. Distance from top of Enclosure) 2” 3/4” 3/4”

    NOTE: To vent the fireplace chase, removal of vent shields from the fireplace is required.

  • Optional Vented Chase - Grill Opening Dimensions

      Width Height
    Front – ZCVRB47 46-3/4” 2-5/8”
    Front – ZCVRB60 60-5/8” 3-5/8”
    Front - ZCVRB72 78-5/8” 3-5/8”
    Sides – ZCVRB47/60 15-1/4” 6-5/8”
    Sides - ZCVRB72 15-1/4” 9"

     

  • Surrounds

      Border Width Border Width Coverage Coverage Sides
      Sides Top/Bottom W H  
    ZCVRB47S1(BL/SS) 1-1/2" 1-1/2" 44-1/2" 18-7/8" 4
    ZCVRB60S1(BL/SS) 1-1/2" 1-1/2" 64" 23" 4
    ZCVRB72S1(BL/SS) 1-1/2" 1-1/2" 76-3/4" 23" 4

     